SPATIAL MAP SHOWING PER UNIT CURRENT DISTRIBUTION
CONFIGURATION 2 -- Front-to-Back Configuration (Directly Across the Heart Area)
+ A B C D E F G H 1.000 J K +
7 0.000
@ 0
--->
0.008
@ 0
--->
0.038
@+13
--->
0.049
@+41
/\
/
0.053
@+32
/\
/
0.101
@+41
/\
/
0.144
@+57
/\
/
0.435
@+61
/\
|
0.422
@+95
/\
|
0.406
@+128
/\
\
0.031
@+115
/\
|
7
6 0.000
@ 0
--->
0.012
@ 0
--->
0.047
@+7
--->
0.048
@+17
--->
0.060
@+35
/\
/
0.105
@+51
/\
/
0.167
@+68
/\
|
0.197
@+86
/\
|
0.188
@+97
/\
|
0.137
@+96
/\
|
0.075
@+102
/\
|
6
5 0.031
@+124
/\
\
0.049
@+94
/\
|
0.076
@+66
/\
|
0.087
@+67
/\
|
0.100
@+73
/\
|
0.116
@+81
/\
|
0.141
@+86
/\
|
0.144
@+83
/\
|
0.128
@+81
/\
|
0.106
@+79
/\
|
0.070
@+76
/\
|
5
4 0.033
@+120
/\
\
0.055
@+108
/\
|
0.075
@+83
/\
|
0.104
@+80
/\
|
0.128
@+86
/\
|
0.142
@+91
/\
|
0.150
@+92
/\
|
0.150
@+84
/\
|
0.153
@+79
/\
|
0.150
@+80
/\
|
0.109
@+78
/\
|
4
3 0.036
@+120
/\
|
0.046
@+125
/\
\
0.046
@+113
/\
|
0.064
@+93
/\
|
0.090
@+101
/\
|
0.117
@+101
/\
|
0.142
@+97
/\
|
0.161
@+86
/\
|
0.174
@+77
/\
|
0.167
@+78
/\
|
0.109
@+86
/\
|
3
2 0.040
@+90
/\
|
0.084
@+117
/\
|
0.105
@+111
/\
|
0.117
@+101
/\
|
0.149
@+109
/\
|
0.210
@+111
/\
|
0.275
@+104
/\
|
0.302
@+90
/\
|
0.277
@+74
/\
|
0.217
@+71
/\
|
0.126
@+72
/\
|
2
1 0.579
@+136
/\
\
0.052
@+139
/\
\
0.069
@+119
/\
|
0.062
@+111
/\
|
0.084
@+125
/\
\
0.136
@+128
/\
\
0.197
@+113
/\
|
0.612
@+119
/\
|
0.643
@+82
/\
|
0.627
@+48
/\
/
0.453
@-141
/
\/
1
+ A B C D E F G H 1.000 J K +
Cell
Entry
Notes
0.###
@++##
--->
Per Unit Current Magnitude
Calculated current direction in degrees (+180, 0, -180)
Approximate graphic current direction (8 sectors in 360 degrees)
Color Codes
Hi+ 0.9-
1.0
&
Bat.
0.8-
0.9
0.7-
0.8
0.6-
0.7
0.5-
0.6
0.4-
0.5
0.3-
0.4
0.2-
0.3
0.1-
0.2
0.0-
0.1
Bat.
"-"
Term
Lo-
Click Here to See Either the Raw Data or the Reduced Data for Configuration 2
FOR RAW DATA VOLTAGE MAP or FOR PER UNIT VOLTAGE MAP

© by Uncle Abdul, 1999. No copies--hardcopy or electronic--may be made without expressed, written permission of the author. This material is presented for informational purposes only and is not represented as nor should it be interpreted as a standard, a specification, a recommended practice, a guideline, or even a professional opinion on the safety of C/BDSM or of any equipment or systems. The author cannot be held responsible for nor does he certify the safety of any equipment or devices that are built, designed, and/or manufactured utilizing this information. In the nature of a textbook the author requests comments on omissions and errors that a reader may find contained herein. The author can be contacted at UncleAbdul@gMail.com.

Return to Experiment INDEX