SPATIAL MAP SHOWING PER UNIT CURRENT DISTRIBUTION
CONFIGURATION 1 -- "Uni-Polar" Nipple to Nipple Configuration
+ A B C D E F G H I J K +
7 0.008
@+90
/\
|
0.015
@+22
--->
0.030
@+16
--->
0.049
@ 0
--->
0.043
@+8
--->
0.037
@ 0
--->
0.045
@+18
--->
0.049
@ 0
--->
0.031
@+22
--->
0.008
@-45
\
\/
0.008
@-90
|
\/
7
6 0.030
@+74
/\
|
0.043
@+53
/\
/
0.056
@+21
--->
0.075
@+5
--->
0.060
@ 0
--->
0.047
@+7
--->
0.061
@+8
--->
0.075
@+5
--->
0.040
@ 0
--->
0.015
@-22
--->
0.022
@-22
--->
6
5 0.065
@+90
/\
|
0.093
@+68
/\
|
0.097
@+50
/\
/
0.110
@+33
/\
/
0.083
@+29
--->
0.056
@+21
--->
0.072
@ 0
--->
0.081
@-6
--->
0.049
@-21
--->
0.034
@-41
\
\/
0.022
@-67
|
\/
5
4 0.087
@+67
/\
|
0.119
@+70
/\
|
0.131
@+56
/\
/
0.148
@+43
/\
/
0.122
@+34
/\
/
0.087
@+22
--->
0.089
@ 0
--->
0.094
@-12
--->
0.073
@-34
\
\/
0.064
@-58
\
\/
0.043
@-82
|
\/
4
3 0.114
@+86
/\
|
0.158
@+71
/\
|
0.153
@+56
/\
/
0.166
@+37
/\
/
0.154
@+29
--->
0.127
@+18
--->
0.118
@+3
--->
0.118
@-13
--->
0.102
@-32
\
\/
0.096
@-57
\
\/
0.066
@-83
|
\/
3
2 0.205
@+87
/\
|
0.271
@+70
/\
|
0.242
@+50
/\
/
0.196
@+35
/\
/
0.183
@+24
--->
0.175
@+9
--->
0.157
@-8
--->
0.153
@-23
--->
0.168
@-38
\
\/
0.166
@-61
|
\/
0.120
@-89
|
\/
2
1 0.434
@+117
/\
|
0.575
@+81
/\
|
0.608
@+41
/\
/
0.137
@+17
--->
0.137
@+17
--->
0.147
@ 0
--->
0.137
@-17
--->
0.117
@-23
--->
0.445
@-40
\
\/
0.406
@-80
|
\/
0.307
@-120
|
\/
1
+ A 1.000 C D E F G H I 1.000 K +
Cell
Entry
Notes
0.###
@+##
--->
Per Unit Current Magnitude
Calculated current direction in degrees (+180, 0, -180)
Approximate graphic current direction (8 sectors in 360 degrees)
Color Codes
Hi+ 0.9-
1.0
&
Bat.
0.8-
0.9
0.7-
0.8
0.6-
0.7
0.5-
0.6
0.4-
0.5
0.3-
0.4
0.2-
0.3
0.1-
0.2
0.0-
0.1
Bat.
"-"
Term
Lo-
Click Here to See Either the Raw Data or the Reduced Data for Configuration 1
FOR RAW DATA VOLTAGE MAP or FOR PER UNIT VOLTAGE MAP

© by Uncle Abdul, 1999. No copies--hardcopy or electronic--may be made without expressed, written permission of the author. This material is presented for informational purposes only and is not represented as nor should it be interpreted as a standard, a specification, a recommended practice, a guideline, or even a professional opinion on the safety of C/BDSM or of any equipment or systems. The author cannot be held responsible for nor does he certify the safety of any equipment or devices that are built, designed, and/or manufactured utilizing this information. In the nature of a textbook the author requests comments on omissions and errors that a reader may find contained herein. The author can be contacted at UncleAbdul@gMail.com.

Return to Experiment INDEX